Witech Micropod2 Program 2005 Chrysler 200 All Keys Lost




Confirmed! wiTech Micropod 2 is able to do online programming to Chrysler including ECU programming and key adding even when all keys are lost. Here you go.

 

Purpose: Micropod 2 clone programs new key fobik to Chrysler 200 when all keys are lost

Car: 2015 Chrysler 200 (The 2015 Chrysler 200, along with other Fiat-based models like the Jeep Renegade, Jeep Cherokee, and Ram Promaster, are all equipped with a rolling PIN Code.)

 

What you need:

Locksmith Identification Number (LSID through NASTF)

Proper keys to be programmed

PIN Code

Laptop

MicroPOD II good quality clone or the genuine

wiTECH diagnostic application

 

Before you begin the programming process, you should the Key Code (key cut code) and Authorized PIN (key programming).

 

VERY VERY VERY IMPORTANT:

    You must be online to program the key with Micropod 2 clone.
    You can pull the PIN Code with OBDSTAR F104 key tool.
    If you input the wrong code for 3 times, it locks the BCM and you cannot service the vehicle for 24 hours.
    The key is one-time programmable. Once married to the vehicle it is locked to the car forever. The key can be erased from the car and put back into the same car, but can’t be switched to another car.
    The placement of the key during initialization is important. It needs to be placed either behind the shifter or in the center console.

 

 

How to program fobik with wiTECH app:

 

Step 1:

Plug the MicroPOD II adapter into the OBD port and connect the USB cable from the device to your laptop. This wakes the BUS on the car.

 

Step 2:






Manually enter the VIN of the vehicle. This gives you access to the module list.  Select the RFH (Radio Frequency Hub) module. This is the module where the key is registered.

 

Step 3:



Next select “Miscellaneous Functions,” then “Program Ignition Fobiks.”  At this point, you are prompted to enter the VIN again, followed by the four-digit PIN Code.

 

Step 4:



After the four-digit pin is entered you are prompted to hit continue to “Program Ignition FOBIK.” Once you hit continue you must press the UNLOCK button on the FOBIK within 30 seconds (the FOBIK needs to be located near the center console during this procedure).

 

Step 5:




Programming of the Ignition FOBIK is now successful. The new key key is accepted into the car, and the ignition will now turn on and start the car. At this point, you also have the option to program a second key with wiTech application.

 


www.cnautotool.com



2022年10月21日星期五

Solve CG FC200 E135 Device not activated

 


How to Solve CG FC200 E135 Device not activated?

Here shares the solution to resolve CG FC200 Error ‘E135: device not activated’.



 the solution:

    FC200 activation requires network connection.

Make sure the computer is connected to the internet with stable signal.

    Connect FC200, ECU and computer again.

Make sure the device connection is normal.

    Update the software

In FC200 software, first click ‘Check for updates’ to check if there is new version for update. If yes, click ‘Firmware upgrade’ to update.



 


2022年10月8日星期六

How to use Cummins INSITE Software to connect to CUMMINS engine

How to use Cummins INSITE Software to connect to CUMMINS engine-1
There Share details of connecting Cummins engines with Cummins INSITE software

Proceed as follows:
Open “Cummins INSITE” via the shortcut on the desktop. Use the status bar to select connection options

How to use Cummins INSITE Software to connect to CUMMINS engine-2
Figure 1.2 – Status bar (Connection Options)

Click the dropdown box on the “Status bar” to view a list of all currently available connection options, or click “Add New” to create one, then click “Next”.
How to use Cummins INSITE Software to connect to CUMMINS engine-3

Figure 1.3 – ECM Connection Wizard

Use the “ECM Connection Type” page, and choose “Datalink Adapter” (Connect using a Datalink Adapter), then click “Next”.
How to use Cummins INSITE Software to connect to CUMMINS engine-4
Figure 1.4 – ECM Connection Type
Choose “Connection Settings”, select your “Datalink Adapter Vendor”, “Datalink Adapter”, and “Datalink Protocol”, then click “Next”.
How to use Cummins INSITE Software to connect to CUMMINS engine-5

Figure 1.5 – Datalink Adapter Vendor

How to use Cummins INSITE Software to connect to CUMMINS engine-6
Figure 1.6 – Datalink Adapter
How to use Cummins INSITE Software to connect to CUMMINS engine-7

Figure 1.7 – Datalink Protocol

Click “Connect to ECM”
-If you are connecting to a new ECM or an ECM without existing ECM passwords, select “None” in the Security Type: dropdown list.
-If you then want to define ECM security type passwords, select ECM Passwords on the Tools menu once connected to the ECM.

The “Work Order Wizard” is automatically displayed for you to create a work order for the selected connection, then click “OK”. NOTE: You can disable the Wizard from starting automatically by unchecking the Enable Work Order Mode checkbox in the Work Orders page of the Options window.

How to use Cummins INSITE Software to connect to CUMMINS engine-8
Figure 1.8 – New Work Order

Wait the “Work Order/Image Creation” until 100% of creating image.

How to use Cummins INSITE Software to connect to CUMMINS engine-9
Figure 1.9 – Work Order/Image Creation

For example, “Fault Codes” display on Cummins INSITE software.
How to use Cummins INSITE Software to connect to CUMMINS engine-10

Figure 2.1 – Fault Codes

How to use Cummins INSITE Software to connect to CUMMINS engine-11
Figure 2.2 – Fault Codes (Overview)

 

Looking forward to your consultation our website sale@cnautotool.com